{"id":5439,"date":"2024-07-09T13:22:46","date_gmt":"2024-07-09T12:22:46","guid":{"rendered":"https:\/\/feig.sunrise-web.net\/?page_id=5439"},"modified":"2025-09-01T14:36:56","modified_gmt":"2025-09-01T13:36:56","slug":"tst-rcca-a","status":"publish","type":"page","link":"https:\/\/www.feig.de\/en\/tst-rcca-a\/","title":{"rendered":"TST-RCCA-A"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":4,"featured_media":5255,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-5439","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":{"content-modul":[{"acf_fc_layout":"modul-columns","content-modul-columns":{"section-headline-group":{"section-eyebrow":"","section-headline":"&nbsp;\r\n<h5><strong>WHY NETWORK YOUR PRODUCTION OR PROCESSES?<\/strong><\/h5>\r\nIncreased productivity, more comfort, less effort: it's worth networking doors with manufacturing processes or intralogistics procedures.\r\n\r\nThe networked factory and the networked building are already a reality today. We help you with the last mile to capture the entire process chain and make your applications \u201cfuture ready\u201d.\r\n\r\n&nbsp;\r\n<h5><strong>WHERE CAN WE HELP YOU?<\/strong><\/h5>\r\nEven now there are various advantages of networking that have become established:\r\n\r\n&nbsp;\r\n<h5><strong>PREDICTIVE MAINTENANCE<\/strong><\/h5>\r\n<ul class=\"component-items\">\r\n \t<li>The systems are maintained in time before failure, but run for as long as possible until then<\/li>\r\n \t<li>Intelligently planned replacement of parts<\/li>\r\n \t<li>Reduction of technical service on site through precise planning<\/li>\r\n \t<li>Reducing the risk of unexpected failures<\/li>\r\n \t<li>Securing sales, because unplanned downtimes cost money<\/li>\r\n \t<li>Improving workforce utilization<\/li>\r\n<\/ul>\r\n&nbsp;\r\n<h5><strong>AUTOMATION USING ROBOTICS<\/strong><\/h5>\r\n<ul class=\"component-items\">\r\n \t<li>Intelligent production processes where robotics handle production at high speed<\/li>\r\n \t<li>Doors as separating protective devices support robotics and improve efficiency<\/li>\r\n \t<li>Reducing human interaction<\/li>\r\n \t<li>Costs and processes are thus optimized<\/li>\r\n<\/ul>\r\n&nbsp;\r\n<h5><strong>INTELLIGENT FACILITY MANAGEMENT<\/strong><\/h5>\r\n<ul class=\"component-items\">\r\n \t<li>Buildings are managed through data and sensors<\/li>\r\n \t<li>A holistic view improves the efficiency of processes<\/li>\r\n \t<li>Cost reduction through intelligent energy management<\/li>\r\n<\/ul>\r\n&nbsp;\r\n\r\nYou need more information? Please contact us via <a href=\"mailto:sales@feig.de\">sales@feig.de<\/a>","section-subheadline":"","headline-animation":"data-aos=\"\""},"columns-repeater":null,"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"","column-reverse":[],"column-align":"gc-left","section-padding":{"section-padding-top-desktop":0,"section-padding-top-mobil":0,"section-padding-bottom-desktop":20,"section-padding-bottom-mobil":0}}}},{"acf_fc_layout":"modul-text-image","content-modul-text-image":{"section-headline-group":{"section-eyebrow":"","section-headline":"<div class=\"csc-header\">\r\n<h4 class=\"csc-firstHeader\" style=\"text-align: center;\">DOOR CONTROLS BECOME NETWORK-CAPABLE\r\nWITH THE COMMUNICATION MODULE TST RCCA-A<\/h4>\r\n<\/div>\r\n<div class=\"content-centered content-centered-none row\"><\/div>","section-subheadline":"","headline-animation":"data-aos=\"\""},"row-repeater":[{"column-content-text":[{"acf_fc_layout":"content-editor-group","content-editor":{"editor":"With the modern communication module TST RCCA-A from FEIG ELECTRONIC, door controls become an integral part of intelligent and automated systems.\r\n\r\nThanks to the PROFINET interface of the TST RCCA-A module, the FEIG controls can be integrated almost anywhere. Doors can be controlled by a higher-level controller via bidirectional communication. The door control also bundles the data from the connected sensors and transmits status, diagnostic or error messages to the central control.\r\n\r\nThe integrated IRT switch enables additional network participants to be connected directly to the door control and thus easy cabling of additional Profinet participants.\r\nIRT stands for \u201cIsochronous Real Time\u201d and enables the use of the TST RCCA-A in networks with real-time communication.\r\n\r\nLooking for more comfort and security features? <a href=\"https:\/\/www.feig.de\/en\/tst-rcca-b-c-d\/\" target=\"_blank\" rel=\"noopener\">Look at our communication module in the variants -B -C and -D<\/a>","editor-readmore":""}}],"column-content-image":{"imagetext":"","badge":null,"image":2661},"column-reverse-mobile":[],"column-align":"image-text"}],"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"","section-padding":{"section-padding-top-desktop":0,"section-padding-top-mobil":0,"section-padding-bottom-desktop":20,"section-padding-bottom-mobil":0}}}},{"acf_fc_layout":"modul-columns","content-modul-columns":{"section-headline-group":{"section-eyebrow":"","section-headline":"","section-subheadline":"","headline-animation":"data-aos=\"\""},"columns-repeater":[{"column-content":[{"acf_fc_layout":"content-editor-group","content-editor":{"editor":"<p style=\"text-align: center;\"><strong>The perfect communication partner for the automation industry:<\/strong> the TST RCCA-A. Discrete wiring is being replaced by digital integration. This enables highly flexible integration into the on-site manufacturing processes.<\/p>\r\n&nbsp;\r\n\r\n[video width=\"1280\" height=\"720\" mp4=\"https:\/\/www.feig.de\/wp-content\/uploads\/TST_RCCA_EN.mp4\"][\/video]\r\n<p style=\"text-align: center;\"><\/p>","editor-readmore":""}}],"column-width":"gc-2-3","column-id":"","column-class":"","column-animation":"data-aos=\"\"","column-vertical-align":"column-align-center"}],"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"rgb(242,243,245)","column-reverse":[],"column-align":"gc-center","section-padding":{"section-padding-top-desktop":20,"section-padding-top-mobil":16,"section-padding-bottom-desktop":60,"section-padding-bottom-mobil":24}}}},{"acf_fc_layout":"modul-columns","content-modul-columns":{"section-headline-group":{"section-eyebrow":"","section-headline":"<h4 class=\"csc-firstHeader\" style=\"text-align: center;\">DOWNLOADS AND FURTHER INFORMATION<\/h4>\r\n&nbsp;\r\n<p style=\"text-align: center;\">Whether technical data, certificates or descriptions, you will find all relevant information about the TST RCCA-A here.<\/p>\r\n&nbsp;\r\n<div>\r\n<div id=\"c3755\" class=\"csc-default\">\r\n<div>\r\n<div id=\"c3741\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h4 class=\"csc-firstHeader\">TECHNICAL DATA<\/h4>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Data Sheet\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Data_sheet_Controller_Accessories_TST_RCCA-A.pdf\" target=\"_blank\" rel=\"noopener\">Data_sheet_Controller_Accessories_TST_RCCA-A.pd<\/a> 331 KB<\/li>\r\n \t<li><a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/TST-RCCA-A-MontageanleitungV4.0-en_UL.pdf\" target=\"_blank\" rel=\"noopener\">TST-RCCA-A-MontageanleitungV3.1-en_UL-1.pdf<\/a> 2 MB<\/li>\r\n<\/ul>\r\n<div class=\"csc-header\">\r\n<h4 class=\"csc-firstHeader\"><strong>CERTIFICATES<\/strong><\/h4>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>PROFINET cERTIFICATE\r\n<a class=\"download\" title=\"PROFINET Zertifikat\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/PN-Zertifikat_TST-RCCA-A_20220421_Z13069.pdf\"><span class=\"csc-uploads-fileName\">PN-Zertifikat_TST-RCCA-A_20220421_Z13069.pdf<\/span>\u00a0<\/a>\u00a0<span class=\"ce-uploads-filesize\">108 KB<\/span><\/li>\r\n \t<li>PROFIenergy Certificate\r\n<a class=\"download\" title=\"PROFIenergy Zertifikat\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/PE-Zertifikat_TST-RCCA-ABCD_20220421_Z40301.pdf\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">PE-Zertifikat_TST-RCCA-ABCD_20220421_Z40301.pdf<\/span>\u00a0<\/a>\u00a0<span class=\"ce-uploads-filesize\">80 KB<\/span><\/li>\r\n<\/ul>\r\n<div id=\"c3743\" class=\"csc-frame csc-frame-indent\">\r\n<h5 class=\"csc-firstHeader\"><strong>VENDOR ID<\/strong><\/h5>\r\n<strong>Name:<\/strong>\u00a0FEIG ELECTRONIC GmbH\r\n<strong>Vendor ID (DECIMAL):<\/strong>\u00a01373\r\n<strong>Vendor ID (HEX):<\/strong>\u00a00x055D\r\n\r\n<\/div>\r\n<div><\/div>\r\n<div><\/div>\r\n<div id=\"c3744\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h5 class=\"csc-firstHeader\"><strong>MINIMUM HARDWARE AND SOFTWARE REQUIREMENTS FOR TST RCCA-A<\/strong><\/h5>\r\n<\/div>\r\n<p class=\"description-headline\"><strong>Hardware<\/strong><\/p>\r\n\r\n<ul class=\"component-items\">\r\n \t<li>Door control of the TST FUx class with current software as of Vxx-08.xx<\/li>\r\n \t<li>ProfiNet\u00ae-capable, higher-level PLC (e.g.: SIEMENS S7-1200)<\/li>\r\n<\/ul>\r\n<p class=\"description-headline\"><strong>Software<\/strong><\/p>\r\n\r\n<ul class=\"component-items\">\r\n \t<li>RCCA device description file, available via <a href=\"https:\/\/login.feig.de\/en\/login\/\" target=\"_blank\" rel=\"noopener\">download area<\/a><\/li>\r\n \t<li>Access to the development environment of the higher-level controller (Recommendation: SIEMENS TIA Portal V15.1 or newer)<\/li>\r\n \t<li>F-CRC Tool\r\n<a class=\"download\" title=\"Download:\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Feig_iPar_CRC-V1.0.6-2-Setup.zip\" target=\"_blank\" rel=\"noopener\">Feig_iPar_CRC V1.0.6-2 - Setup.zip\u00a0<\/a><\/li>\r\n<\/ul>\r\n&nbsp;\r\n\r\n<\/div>\r\n<div>\r\n<div class=\"csc-header\">\r\n<h5 class=\"csc-firstHeader\" style=\"text-align: left;\"><strong>MODULE LIST OF TRANSMITTED DATA<\/strong><\/h5>\r\n<\/div>\r\n<p style=\"text-align: left;\">The following data is exchanged between the PLC and the door control:<\/p>\r\n\r\n<div id=\"c3749\" class=\"csc-frame csc-frame-indent\">\r\n\r\n<img class=\"aligncenter wp-image-4578 size-large\" src=\"https:\/\/www.feig.de\/wp-content\/uploads\/csm_Modulliste-TST-RCCA_39f0d2419c-1024x514.jpg\" alt=\"\" width=\"1024\" height=\"514\" \/>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Download: Module Lists\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Modulliste_RCCA-A-1.xlsx\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/Modulliste_RCCA-A-1.xlsx<\/a><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3754\" class=\"csc-default\">\r\n<div>\r\n<h4><\/h4>\r\n<h5 class=\"csc-header\"><strong>DESCRIPTION FILES<\/strong><\/h5>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>PROFINET device description file\r\n<a class=\"download\" title=\"PROFINET Ger\u00e4tebeschreibungsdatei\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/GSDML-V2.35-FEIG-TST_RCCA-20220216.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">GSDML-V2.35-FEIG-TST_RCCA-20220216.zip<\/span>\u00a0<\/a>\u00a0<span class=\"ce-uploads-filesize\">32 KB<\/span><\/li>\r\n<\/ul>\r\n<\/div>\r\n<\/div>\r\n<div id=\"c3755\" class=\"csc-default\">\r\n<div>\r\n<div id=\"c4219\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h4><\/h4>\r\n<h5 class=\"csc-firstHeader\"><strong>APPLICATION INSTRUCTIONS<\/strong><\/h5>\r\n<\/div>\r\n<\/div>\r\n<div id=\"c3741\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\"><\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<h5 class=\"csc-firstHeader\"><strong>Display of communication data<\/strong><\/h5>\r\nExample of displaying the communication data of a SIEMENS PLC S7-1200 in TIA Portal V15.1\r\n\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_for_using_an_RCCA-A_with_HMI_EN.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_for_using_an_RCCA-A_with_HMI_EN.pdf<\/a>\r\n\r\n&nbsp;\r\n<h5 class=\"csc-firstHeader\"><strong>Network Topologies<\/strong><\/h5>\r\n<div>\r\n<div id=\"c3769\" class=\"csc-frame csc-frame-indent\">\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Examples of network topologies in a Siemens S7 network\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/RCCA_Network_Topology_EN.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/RCCA_Network_Topology_EN.pdf<\/a><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3767\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h5><\/h5>\r\n<h5 class=\"csc-firstHeader\"><strong>Module library<\/strong><\/h5>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Module library for the generic use of the TST RCCA-A in the SIEMENS TIA Portal\r\n<a class=\"download\" title=\"Baustein-Bibliothek fu\u0308r die generische Verwendung der TST RCCA-A im SIEMENS TIA Portal\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Feig_RCCA_V1.1.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">Feig_RCCA_V1.1.zip<\/span><\/a>\u00a0<span class=\"ce-uploads-filesize\">614 KB<\/span><\/li>\r\n \t<li>Module library for the generic use of the TST RCCA-A in the SIEMENS TIA Portal with HMI\r\n<a class=\"download\" title=\"Baustein-Bibliothek fu\u0308r die generische Verwendung der TST RCCA-A im SIEMENS TIA Portal mit HMI\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Feig_RCCA_incl._HMI_V1.1.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">Feig_RCCA_incl._HMI_V1.1.zip<\/span><\/a>\u00a0<span class=\"ce-uploads-filesize\">742 KB<\/span><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3771\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h5><\/h5>\r\n<h5 class=\"csc-firstHeader\"><strong>Application Example: Single Drive<\/strong><\/h5>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Application example single drive without HMI\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_single_Drive_Without_HMI_EN.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_single_Drive_Without_HMI_EN.pdf<\/a><\/li>\r\n \t<li>Example project with a SIEMENS PLC S7-1200 in TIA Portal V15.1\r\n<a class=\"download\" title=\"Beispiel-Projekt mit einer SIEMENS SPS S7-1200 im TIA Portal V15.1\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/S7-1200_RCCA_A.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">S7-1200_RCCA_A.zip<\/span><\/a>\u00a0<span class=\"ce-uploads-filesize\">2 MB<\/span><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3773\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h5><\/h5>\r\n<h5 class=\"csc-firstHeader\"><strong>Application Example: Setting\/reading IOs<\/strong><\/h5>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Application description for setting virtual inputs and reading out the output status of the door controller with TST RCCA and a SIEMENS PLC S7-1200\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_RCCA-A_Interaction_with_TST.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_RCCA-A_Interaction_with_TST.pdf<\/a><\/li>\r\n \t<li>Example project with a SIEMENS PLC S7-1200 in TIA Portal V15.1\r\n<a class=\"download\" title=\"Beispiel-Projekt mit einer SIEMENS SPS S7-1200 im TIA Portal V15.1\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/S7-1200_RCCA_A_Interact_with_TST.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">S7-1200_RCCA_A_Interact_with_TST.zip<\/span><\/a>\u00a0<span class=\"ce-uploads-filesize\">3 MB<\/span><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3775\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h5><\/h5>\r\n<h5 class=\"csc-firstHeader\"><strong>Application Example: Using the DIs<\/strong><\/h5>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Application description for reading out the digital inputs of the TST RCCA-A with a SIEMENS PLC S7-1200\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_RCCA-A_Digital_Inputs_EN.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_RCCA-A_Digital_Inputs_EN.pdf<\/a><\/li>\r\n \t<li>Example project with a SIEMENS SPS S7-1200 in TIA Portal V15.1\r\n<a class=\"download\" title=\"Beispiel-Projekt mit einer SIEMENS SPS S7-1200 im TIA Portal V15.1\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/S7-1200_RCCA_A_Digital_Inputs.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">S7-1200_RCCA_A_Digital_Inputs.zip<\/span><\/a>\u00a0<span class=\"ce-uploads-filesize\">3 MB<\/span><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3777\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\">\r\n<h5><\/h5>\r\n<h5 class=\"csc-firstHeader\"><strong>Application Example: HMI<\/strong><\/h5>\r\n<\/div>\r\n<ul class=\"csc-uploads csc-uploads-0 list-unstyled\">\r\n \t<li>Application description for control, display and evaluation via HMI\r\n<a href=\"https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_for_using_an_RCCA-A_with_HMI_EN.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.feig.de\/wp-content\/uploads\/Application_Example_for_using_an_RCCA-A_with_HMI_EN.pdf<\/a><\/li>\r\n \t<li>Example project with a SIEMENS SPS S7-1200 in TIA Portal V15.1\r\n<a class=\"download\" title=\"Beispiel-Projekt mit einer SIEMENS SPS S7-1200 im TIA Portal V15.1\" href=\"https:\/\/www.feig.de\/wp-content\/uploads\/S7-1200_RCCA_A_Interact_with_TST_incl._HMI.zip\" target=\"_blank\" rel=\"noopener\"><span class=\"csc-uploads-fileName\">S7-1200_RCCA_A_Interact_with_TST_incl._HMI.zip<\/span><\/a>\u00a0<span class=\"ce-uploads-filesize\">8 MB<\/span><\/li>\r\n<\/ul>\r\n<\/div>\r\n<div id=\"c3741\" class=\"csc-frame csc-frame-indent\">\r\n<div class=\"csc-header\"><\/div>\r\n<\/div>\r\n<div id=\"c3763\" class=\"csc-frame csc-frame-indent\"><\/div>\r\n<div id=\"c3765\" class=\"csc-default\">\r\n<div><\/div>\r\n<\/div>\r\n<\/div>","section-subheadline":"","headline-animation":"data-aos=\"\""},"columns-repeater":null,"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"","column-reverse":[],"column-align":"gc-left","section-padding":{"section-padding-top-desktop":0,"section-padding-top-mobil":0,"section-padding-bottom-desktop":20,"section-padding-bottom-mobil":0}}}},{"acf_fc_layout":"modul-accordion","content-modul-accordion":{"section-headline-group":{"section-eyebrow":"","section-headline":"<h4 class=\"csc-firstHeader\" style=\"text-align: center;\">FREQUENTLY ASKED QUESTIONS (FAQ)<\/h4>","section-subheadline":"","headline-animation":"data-aos=\"\""},"accordion-repeater":[{"accordion-title":"There is no RCCA module for integration in the control program","accordion-editor":"Load the GSDML file (available as a free download on this support website) into your development environment."},{"accordion-title":"The RCCA is integrated in the project, but the PLC reports it as \"not accessible\"","accordion-editor":"<ol>\r\n \t<li>Make sure that the correct hardware version (RCCA-A\/B\/C\/D) has been configured. The hardware version is reported in the TIA portal via \"online\" \u2192 \"accessible devices\".<\/li>\r\n \t<li>Check the Profinet connection between the RCCA and the higher-level controller. (see \"Network topologies\" on the support website)<\/li>\r\n \t<li>Ensure that the RCCA module is supplied with power.<\/li>\r\n \t<li>Check the device name of the target device. On delivery, this is \"tst-rcca\"<\/li>\r\n<\/ol>"},{"accordion-title":"The RCCA is integrated in the project, but the \"TST Door_1\" module is not accessible","accordion-editor":"<ol>\r\n \t<li>Check the power supply to the RCCA.<\/li>\r\n \t<li>Check parameter P.804, which must be parameterized to \"1\".<\/li>\r\n \t<li>Check the correct installation of the eight-pole connection cable on the underside of the RCCA when it is de-energized.<\/li>\r\n<\/ol>"},{"accordion-title":"Communication between the door control unit, RCCA and PLC is established. But no movement commands are executed","accordion-editor":"<ol>\r\n \t<li>Make sure that the door control unit does not report an error and can be operated in automatic mode.<\/li>\r\n \t<li>Make sure that both the bit for direction or stop and the corresponding mask are set for a move command. (see \"Module list of transmitted data\" \u2192\u00a0 \"Send\" \u2192\u00a0Byte\u00a010 on the support website) To simplify communication, we recommend using the \"Feig RCCA [incl. HMI] V1.1\" library, download from this support website.<\/li>\r\n<\/ol>"}],"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"","column-reverse":[],"column-align":"gc-left","section-padding":{"section-padding-top-desktop":0,"section-padding-top-mobil":0,"section-padding-bottom-desktop":80,"section-padding-bottom-mobil":0}}}},{"acf_fc_layout":"modul-columns","content-modul-columns":{"section-headline-group":{"section-eyebrow":"","section-headline":"<h4 class=\"csc-firstHeader\" style=\"text-align: center;\">ANY MORE QUESTIONS?<\/h4>\r\n&nbsp;\r\n<p style=\"text-align: center;\">We 're more than happy to help you with inquiries and other concerns. Simply contact our support or sales department.<\/p>","section-subheadline":"","headline-animation":"data-aos=\"\""},"columns-repeater":[{"column-content":[{"acf_fc_layout":"content-btn-group","content-btn":{"btn-link":{"title":"Contact sales","url":"mailto:sales@feig.de","target":""},"btn-style":"btn-style-01","btn-animation":"data-aos=\"\"","btn-align":"btn-align-center","btn-class":""}}],"column-width":"gc-1-2","column-id":"","column-class":"","column-animation":"data-aos=\"\"","column-vertical-align":"column-align-top"},{"column-content":[{"acf_fc_layout":"content-btn-group","content-btn":{"btn-link":{"title":"Contact support","url":"mailto:tst-support@feig.de","target":""},"btn-style":"btn-style-01","btn-animation":"data-aos=\"\"","btn-align":"btn-align-center","btn-class":""}}],"column-width":"gc-1-2","column-id":"","column-class":"","column-animation":"data-aos=\"\"","column-vertical-align":"column-align-top"}],"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"","column-reverse":[],"column-align":"gc-left","section-padding":{"section-padding-top-desktop":0,"section-padding-top-mobil":0,"section-padding-bottom-desktop":80,"section-padding-bottom-mobil":0}}}},{"acf_fc_layout":"modul-contactwidget","content-modul-contactwidget":{"section-headline-group":{"section-eyebrow":"","section-headline":"<h4 class=\"csc-firstHeader\" style=\"text-align: center;\">ANY MORE QUESTIONS?<\/h4>\r\n&nbsp;\r\n<p style=\"text-align: center;\">We 're more than happy to help you with inquiries and other concerns. Simply contact our support or sales department.<\/p>","section-subheadline":"","headline-animation":"data-aos=\"\""},"contact-widget-indi":{"widget-container-1":{"titel":"","text":"","icon":null,"link":null},"widget-container-2":{"titel":"","text":"","icon":null}},"section-settings":{"section-id":"","section-class":"","section-animation":"data-aos=\"\"","section-bg-color":"","section-padding":{"section-padding-top-desktop":0,"section-padding-top-mobil":0,"section-padding-bottom-desktop":80,"section-padding-bottom-mobil":0}}}}]},"_links":{"self":[{"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/pages\/5439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/comments?post=5439"}],"version-history":[{"count":17,"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/pages\/5439\/revisions"}],"predecessor-version":[{"id":8964,"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/pages\/5439\/revisions\/8964"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/media\/5255"}],"wp:attachment":[{"href":"https:\/\/www.feig.de\/en\/wp-json\/wp\/v2\/media?parent=5439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}