Icon Schnittstelle

Safety module with PROFIsafe interface

Icon Check

PROFINET IRT switch

Icon sicher

Secure output contact (FDO) for stopping the door control unit

Connection of up to 4 IO-Link devices

Product description
Technical specifications
Downloads
Product description

Machine safety gates offer optimal protection for workers within automated manufacturing processes. For this purpose, there are safe sensors on the gate that monitor various safety-relevant parameters and are in direct dialogue with the higher-level process control. The FEIG control TST FUxF in combination with the communication module TST RCCA-B/-C/-D makes it possible to bundle the information from the sensors and the gate and transmit it to the higher-level process control via PROFINET.

Special features

  • Safety module with PROFIsafe interface
  • PROFINET Switch for connecting further PROFINET participants
  • 6 secure inputs (FDI) for external safety sensors
  • Secure output contact (FDO) for secure stopping of the door control unit
  • Connection of up to 4 IO-Link Devices
  • 6 further inputs without safety function

Here you will find everything you need for a successful integration:
Microsite TST-RCCA-B-C-D

Learn more:

Technical specifications
Dimensions (w x h x d)
84 mm x 118 mm x 26,1 mm (with plug-in block terminals)
Protection class
open frame
Power supply voltage
19,2 / 24 / 30 VDC (DIN EN 61131-2)
Supply type
SELV
Power consumption
2.4 W ... 240 W
Current consumption
unloaded 85 mA / loaded max. 10,5 A
Temperature range operation
−20 °C bis +70 °C
Relative air humidity
up to 90 % (non-condensing)